2025-04-15https://repository.covenantuniversity.edu.ng/handle/123456789/48357This work investigated the effect of cone inclination on the performance of cylindrical-conical tangential entry cyclone separator using four different cyclone models. Efficiency determination was achieved by weight difference between the dust loaded and the dust retained while velocity was measured with a pitot tube. Correlation coefficient values ranged between 0.83-0.97, indicating positive correlation. In all cases, efficiency attained highest and least values at 11o and 2o respectively. The optimum cyclone design observed was the 2D2D model.TP Chemical technologyEFFECT OF CONE INCLINATION ON EFFICIENCY OF CYCLONE SEPARATORSArticle